Source code for maxwelllink.matter.md.md_engine

# --------------------------------------------------------------------------------------#
# Copyright (c) 2026 MaxwellLink                                                        #
# This file is part of MaxwellLink. Repository: https://github.com/TaoELi/MaxwellLink   #
# If you use this code, always credit and cite arXiv:2512.06173.                        #
# See AGENTS.md and README.md for details.                                              #
# --------------------------------------------------------------------------------------#

"""
Central built-in classical molecular-dynamics (MD) engine of MaxwellLink.
"""

from dataclasses import dataclass

import numpy as np

from maxwelllink.units import BOHR_PER_ANG, FS_TO_AU, K_TO_AU
from maxwelllink.tools.xyz_helper import read_xyz, read_xyz_frames
from maxwelllink.tools.recorders import (
    PropertyRecorder,
    XYZTrajectoryWriter,
    output_filename,
)

from ..helpers import THREADS_PER_BLOCK, to_host
from .force_fields import DummyForceField, _FORCE_FIELDS, replicate_cell
from .kernels.kernels_integrators import build_integrator_kernels

# The per-molecule properties every MD driver records.
_BASE_RECORD_NAMES = ("temperature_K", "energy_au", "stretch_au", "bend_au",)

_ROTATION_COMPONENT_NAMES = (
    "kinetic_rot_1_au",
    "kinetic_rot_2_au",
    "kinetic_rot_3_au",
)

_FULL_RECORD_NAMES = (
    "temperature_K",
    "energy_au",
    "stretch_au",
    "bend_au",
    "kinetic_au",
    "potential_au",
    "kinetic_trans_au",
    "kinetic_rot_au",
    *_ROTATION_COMPONENT_NAMES,
    "kinetic_vib_au",
    "energy_vib_au",
)
# Properties needed to calculate each derived quantity.
_PROPERTY_DEPENDENCIES = {
    "temperature_K": ("kinetic_au",),
    "energy_au": ("kinetic_au", "potential_au"),
    "energy_vib_au": (
        "kinetic_vib_au",
        "stretch_au",
        "bend_au",
    ),
}

[docs] @dataclass(frozen=True, eq=False) class MDStepResult: """ Columnar physics outputs of one engine step (contiguous host arrays). All arrays are host (NumPy) arrays in atomic units for a batch of ``num`` systems; the field names match the aggregated hub's ``BatchStepResult`` so the batch driver can forward them unchanged. Attributes ---------- amplitude_au : numpy.ndarray, shape (num, 3) Source amplitude ``dmu/dt`` consumed by the EM solver. dipole_half_au : numpy.ndarray, shape (num, 3) Dipole half a step after the force time (relative to the baseline). dipole_force_au : numpy.ndarray, shape (num, 3) Dipole at the force time (relative to the baseline). energy_au : numpy.ndarray, shape (num,) Total (kinetic + potential) energy of every system. """ amplitude_au: np.ndarray dipole_half_au: np.ndarray dipole_force_au: np.ndarray energy_au: np.ndarray
[docs] class MDEngine: """ Batch-first classical-MD propagator with a pluggable force field. Not used directly by users. """
[docs] def __init__( self, ff="qtip4pf", n_molecules=None, positions=None, xyz=None, batch_xyz=None, box=None, replicate=None, rcut=None, ewald_wrcut=None, thermostat: str = "nve", temperature_K: float = 300.0, friction_fs: float = 100.0, init_velocities: bool = True, pre_nvt: bool = False, pre_nvt_duration_ps: float = 20.0, reset_dipole: bool = True, seed: int = 0, force_evaluator: str = "auto", property_filename=None, traj_filename=None, record_every_steps: int = 10, record_max_steps=None, checkpoint: bool = False, restart: bool = False, verbose: bool = False, *, property_list="base", traj_content="positions", pre_nvt_timestep_fs: float | None = None, pre_nvt_friction_fs: float = 100.0, num: int = 1, xp=np, label: str = "MDEngine", ): """ Validate the run parameters and build the force field. Parameters ---------- ff : str or DummyForceField, default: 'qtip4pf' Name of a registered force field (``'qtip4pf'`` for flexible water, ``'co2jcp2021'`` for flexible CO2, ``'cs2compass'`` for flexible CS2, ``'ch4compass'`` for flexible CH4), or an already constructed :class:`DummyForceField` instance. n_molecules : int, optional Number of molecules to build when ``positions`` is not given (before any ``replicate``). If ``None`` (the default) each force field applies its own default count (32 for water, 36 for CO2 and CS2, 100 for CH4, which load the bundled bulk boxes). positions : array-like of float, shape (n_atoms, 3), optional Initial atomic positions in Bohr. If ``None`` the force field builds a default geometry from ``n_molecules`` (and ``box``). xyz : str, optional Path to an XYZ file (Angstrom) to take the starting geometry from, with the atoms in the order the force field expects (``[C, O, O, ...]`` for CO2, ``[O, H, H, ...]`` for water, ``[C, S, S, ...]`` for CS2, ``[C, H, H, H, H, ...]`` for CH4). Overrides ``positions``; but this also gives coordinates only, so a periodic system still needs ``box``. batch_xyz : str, optional Path to a multi-frame XYZ file (Angstrom) that gives every molecule its own starting geometry: molecule ``m`` starts from frame ``m``, so a batch of drivers, or several batches, read consecutive frames and the same molecule ID always gets the same frame. Every frame must list the same atoms; there must be more frames than the largest molecule ID. Frame 0 doubles as the template geometry when neither ``xyz`` nor ``positions`` is given. box : float or array-like of float, shape (3,), optional Periodic box lengths in Bohr. ``None`` treats the system as a finite cluster. replicate : int or array-like of int, shape (3,), optional Replicate the periodic cell. The molecules and the box lengths grow together, so the density is unchanged. rcut : float, optional Real-space cutoff in Bohr for the periodic non-bonded sums. ewald_wrcut : float, optional Real-space cutoff in Bohr for the Ewald sum (periodic electrostatics). thermostat : {'nve', 'nvt'}, default: 'nve' Ensemble. ``'nve'`` is plain velocity Verlet; ``'nvt'`` adds a Langevin (Ornstein-Uhlenbeck) thermostat. temperature_K : float, default: 300.0 Target temperature in Kelvin (NVT) and temperature for the initial Maxwell-Boltzmann velocities. friction_fs : float, default: 100.0 Langevin relaxation time in femtoseconds (``gamma = 1 / tau``). Only used when ``thermostat == 'nvt'``. init_velocities : bool, default: True Whether to sample initial velocities from a Maxwell-Boltzmann distribution at ``temperature_K``. If ``False`` the system starts at rest. pre_nvt : bool, default: False Whether to thermally equilibrate the system inside :meth:`initialize` before any production dynamics. The random seed is offset by the molecule ID so that different molecules are decorrelated even at the same ``seed``. pre_nvt_duration_ps : float, default: 20.0 Duration of the pre-NVT equilibration in picoseconds. It uses a Langevin thermostat at ``temperature_K`` with ``pre_nvt_friction_fs`` damping, regardless of the production ``thermostat``. pre_nvt_friction_fs : float, default: 100.0 Pre-NVT Langevin relaxation time in femtoseconds; must be finite and positive. Independent of the production ``friction_fs``. pre_nvt_timestep_fs : float, optional Pre-NVT timestep in femtoseconds; None uses the coupling timestep. The coupling timestep is restored after equilibration. reset_dipole : bool, default: True Whether to report the dipole moment relative to its value at time zero. seed : int, default: 0 Base seed; system ``molecule_id`` draws from ``seed + molecule_id``. force_evaluator : {'auto', 'numba', 'numpy'}, default: 'auto' Which force evaluator to use. ``'numba'`` uses the compiled loop-form kernels, which are typically several times faster than the array-at-a-time NumPy reference and allocate no ``(na, na, 3)`` temporaries; ``'numpy'`` forces the reference implementation. ``'auto'`` picks ``'numba'`` whenever the force field provides a compiled-kernel description and silently falls back to ``'numpy'`` when it does not. The GPU backend always runs the compiled kernels. property_filename : str, optional Turns on a run-time record of per-molecule properties written to this file every ``record_every_steps`` production steps: HDF5, streamed while the run goes, unless the name ends in ``.npz`` or ``h5py`` is missing. property_list : str or list or tuple, default: "base" Properties written to property_filename. Only used when property_filename is set. "base" selects _BASE_RECORD_NAMES; "all" selects _FULL_RECORD_NAMES. Other strings use semicolons between property names. Lists and tuples are also accepted. Duplicate names are removed while preserving their first occurrence. traj_filename : str, optional Extended-XYZ output with one frame per independent system every ``record_every_steps`` production steps. Positions are in Angstrom, atomic velocities in Bohr per atomic time, and body-frame angular velocities in inverse atomic time. Angular output automatically includes the three corresponding principal moments of inertia in electron-mass times Bohr-squared units. A system may contain multiple physical molecules; each molecule's six values are repeated for all its atoms. traj_content : str, default: "positions" Content to include in the trajectory file: "positions", "velocities", "angular_velocity_body", or "all". Angular output contains three angular-velocity components followed by their three principal moments of inertia. "all" includes positions, atomic velocities, and these six angular-output columns. Only used when ``traj_filename`` is set. Velocities and angular velocities are sampled before the final Langevin O half-step, at the same state as the kinetic properties. Body-frame components use instantaneous principal axes ordered by decreasing moment of inertia; their signs and degenerate directions are not tracked between frames. record_every_steps : int, default: 10 Record every this many production steps, for both files. record_max_steps : int, optional Stop recording after this many records; ``None`` for no cap. checkpoint : bool, default: False Whether the owning front end checkpoints this engine's state. restart : bool, default: False Whether :meth:`initialize` restores a checkpointed state (handed in by the front end) instead of pre-equilibrating. verbose : bool, default: False Kept for the front ends; the engine itself never prints per step. num : int, keyword-only, default: 1 Number of independent systems advanced together. xp : module, keyword-only, default: numpy Array module exposing the NumPy API (``numpy`` or ``cupy``). label : str, keyword-only, default: 'MDEngine' Name used in printed messages, so each front end reports as itself. """ self.xp = xp self.num = int(num) if self.num <= 0: raise ValueError("num must be a positive integer.") self._on_gpu = getattr(xp, "__name__", "") == "cupy" self._label = str(label) self.thermostat = str(thermostat).lower() if self.thermostat not in ("nve", "nvt"): raise ValueError("thermostat must be 'nve' or 'nvt'.") self.temperature_K = float(temperature_K) self.friction_fs = float(friction_fs) self.init_velocities = bool(init_velocities) self.pre_nvt = bool(pre_nvt) self.pre_nvt_duration_ps = float(pre_nvt_duration_ps) self.pre_nvt_friction_fs = float(pre_nvt_friction_fs) if not np.isfinite(self.pre_nvt_friction_fs) or self.pre_nvt_friction_fs <= 0: raise ValueError("pre_nvt_friction_fs must be finite and positive.") self.pre_nvt_timestep_fs = ( None if pre_nvt_timestep_fs is None else float(pre_nvt_timestep_fs) ) if self.pre_nvt_timestep_fs is not None and ( not np.isfinite(self.pre_nvt_timestep_fs) or self.pre_nvt_timestep_fs <= 0 ): raise ValueError("pre_nvt_timestep_fs must be finite and positive.") self.reset_dipole = bool(reset_dipole) self.seed = int(seed) self.kT = K_TO_AU * self.temperature_K self.checkpoint = bool(checkpoint) self.restart = bool(restart) self.verbose = bool(verbose) # run-time trajectory output, opened in initialize() once the molecule IDs and # the time step are known self.property_filename = ( None if property_filename is None else str(property_filename) ) self.traj_filename = None if traj_filename is None else str(traj_filename) self.traj_content = str(traj_content).strip().lower() if self.traj_content not in ("positions", "velocities", "angular_velocity_body", "all"): raise ValueError("traj_content must be positions, velocities, angular_velocity_body, or all.") self._write_trajectory_velocities = ( self.traj_filename is not None and self.traj_content in ("velocities", "all") ) self._write_angular_velocity_body = ( self.traj_filename is not None and self.traj_content in ("angular_velocity_body", "all") ) self.record_every_steps = int(record_every_steps) self.record_max_steps = record_max_steps self._recorder = None self._trajectory = None self._step_index = 0 # production steps taken; not part of a snapshot # the starting geometry from XYZ files: one for all, or one frame per molecule # (picked by molecule ID in initialize()); Angstrom in the files, Bohr here self.batch_frames = None elements = None if batch_xyz is not None: elements, frames = read_xyz_frames(batch_xyz) self.batch_frames = frames * BOHR_PER_ANG if xyz is None and positions is None: positions = self.batch_frames[0] if xyz is not None: elements, positions = read_xyz(xyz) positions = positions * BOHR_PER_ANG # build the force field: a registered name, or a ready-made instance if isinstance(ff, DummyForceField): if any( option is not None for option in ( n_molecules, positions, box, replicate, rcut, ewald_wrcut, ) ): raise ValueError( "a force-field instance carries its own geometry; pass " "n_molecules/positions/xyz/batch_xyz/box/replicate/rcut/" "ewald_wrcut to its constructor instead." ) self.ff = ff else: key = str(ff).lower() if key not in _FORCE_FIELDS: raise ValueError( "Unknown force field %r. Available: %s" % (ff, ", ".join(sorted(_FORCE_FIELDS))) ) # the universal MD parameters are the common force-field constructor API; # forward n_molecules only when set so each force field can apply its own # default (e.g. the 32-molecule water box) when it is left unspecified ff_params = dict( positions=positions, box=box, rcut=rcut, ewald_wrcut=ewald_wrcut ) if n_molecules is not None: ff_params["n_molecules"] = n_molecules if replicate is not None: ff_params["replicate"] = replicate self.ff = _FORCE_FIELDS[key](**ff_params) self.ff_name = self.ff.name self.n_molecules = getattr(self.ff, "n_molecules", 1) # the XYZ files describe the cell before replication; the per-molecule # starting geometries of batch_xyz are tiled the same way as the template images = int(np.prod(getattr(self.ff, "replicate", 1))) expected = list(self.ff.molecule_symbols) * (self.n_molecules // images) if elements is not None and expected and list(elements) != expected: raise ValueError( f"the XYZ atoms do not follow the {self.ff_name} force field's order " f"{list(self.ff.molecule_symbols)} per molecule." ) if self.batch_frames is not None and images > 1: self.batch_frames, _, _ = replicate_cell( self.batch_frames, self.ff.box / self.ff.replicate, self.ff.replicate ) # Pick the CPU force evaluator; the GPU path always runs the compiled kernels evaluator = str(force_evaluator).lower() if evaluator not in ("auto", "numba", "numpy"): raise ValueError("force_evaluator must be 'auto', 'numba' or 'numpy'.") self.force_evaluator = "numpy" if (evaluator != "numpy" or self._on_gpu) and self.ff.has_compiled_kernels: self.force_evaluator = "numba" elif evaluator == "numba" or self._on_gpu: raise NotImplementedError( f"Force field {self.ff.name!r} provides no compiled kernels; " f"use force_evaluator='numpy' on the CPU." ) # geometry template and bookkeeping shared by every front end self.n_atoms = self.ff.n_atoms self.x0 = np.ascontiguousarray(self.ff.positions, dtype=float) self.n_terms = len(self.ff.reported_term_names) # Disable property recording unless a filename is provided. self.record_names = () self.compute_names = () if self.property_filename is not None: # Parse the requested output properties. if isinstance(property_list, str): option = property_list.strip() if option.lower() == "base": requested_names = _BASE_RECORD_NAMES elif option.lower() == "all": requested_names = _FULL_RECORD_NAMES else: requested_names = option.split(";") elif isinstance(property_list, (list, tuple)): requested_names = property_list else: raise TypeError("property_list must be a string, a list or a tuple.") # Check types before stripping whitespace and removing duplicates. if any(not isinstance(name, str) for name in requested_names): raise TypeError("Every property name must be a string.") # Preserve the first occurrence of each property. requested_names = tuple(dict.fromkeys(name.strip() for name in requested_names)) if not requested_names or any(not name for name in requested_names): raise ValueError("property_list contains no name or an empty name.") unknown_names = tuple(name for name in requested_names if name not in _FULL_RECORD_NAMES) if unknown_names: raise ValueError( f"Unknown properties: {unknown_names}. " f"Allowed properties: {_FULL_RECORD_NAMES}" ) # Store the output tuple in the requested order. self.record_names = requested_names # Add each property's dependencies before the property itself. compute_names = () for name in self.record_names: compute_names += ( _PROPERTY_DEPENDENCIES.get(name, ()) + (name,)) # Store the calculation tuple with ordered deduplication. self.compute_names = tuple(dict.fromkeys(compute_names)) # element symbols of the geometry, for the trajectory file self.symbols = ( list(self.ff.molecule_symbols) * self.n_molecules or ["X"] * self.n_atoms ) self.dt = 0.0 # shared time step in a.u. self.t = 0.0 # current time in a.u. self.molecule_ids = () # molecule IDs, set in initialize() self._rngs = () # one host generator per molecule, set in initialize() self.x = self.p = self.F = None # system state, set in initialize() self._terms = None # (num, n_terms) force-field energy terms of the last forces self.c1h = 1.0 # Langevin O half-step scaling self.mu_initial = None # dipole baseline, set in initialize() self.force_kernels = None # the force field's kernels, built in initialize()
# ----------------------- heavy-load initialization ------------------------------
[docs] def initialize(self, dt_au, molecule_ids, restart_state=None): """ Allocate the batch state, then restore a checkpoint or pre-equilibrate. Parameters ---------- dt_au : float The shared time step in atomic units (a.u.). molecule_ids : array-like of int Molecule IDs assigned by the front end; must number exactly ``num``. restart_state : dict, optional A state produced by :meth:`state_dict` (front ends read it from their checkpoint files). Only applied when the engine was built with ``restart=True`` and ``checkpoint=True``; a restart skips the pre-NVT equilibration even when no state could be read. Raises ------ ValueError If the number of molecule IDs does not match ``num``, or the restart state holds a differently shaped batch. """ xp, n, na = self.xp, self.num, self.n_atoms self.molecule_ids = tuple(int(mid) for mid in molecule_ids) if len(self.molecule_ids) != n: raise ValueError( f"{self._label} expected {n} molecule ids, " f"got {len(self.molecule_ids)}." ) self.dt = float(dt_au) self.t = 0.0 # Force evaluator: the compiled kernels of the force field, or its NumPy # reference compute() when force_evaluator='numpy' (CPU only). if self.force_evaluator == "numba": self.force_kernels = self.ff.build_force_kernels(xp, THREADS_PER_BLOCK) mass = self.force_kernels.masses # (na, 1), per atom qeff = self.force_kernels.charges_eff # (na, 1), per atom else: mass = self.ff.masses # (na, 1), per atom qeff = None # dipoles then come from ff.dipole()/ff.dipole_velocity() self._mass_host = mass # Langevin O half-step coefficients (exp(-0.5 * gamma * dt)) if self.thermostat == "nvt": gamma = 1.0 / (self.friction_fs * FS_TO_AU) self.c1h = float(np.exp(-0.5 * gamma * self.dt)) else: self.c1h = 1.0 self.noise = np.sqrt(mass * self.kT * (1.0 - self.c1h**2)) # (na, 1) # One host generator per molecule, seeded from seed + molecule_id. It draws # the initial momenta on both backends and, on the CPU backend, the Langevin # noise as well; the GPU backend seeds its device streams the same way below. self._rngs = [ np.random.default_rng(self.seed + mid) for mid in self.molecule_ids ] # positions: one geometry replicated, or every molecule's own frame; momenta: # one draw per molecule if self.batch_frames is None: x_host = np.broadcast_to(self.x0, (n, na, 3)).copy() else: if max(self.molecule_ids) >= len(self.batch_frames): raise ValueError( f"batch_xyz holds {len(self.batch_frames)} frames, fewer than " f"molecule ID {max(self.molecule_ids)} needs." ) x_host = np.array([self.batch_frames[mid] for mid in self.molecule_ids]) p_host = np.zeros((n, na, 3)) if self.init_velocities: sigma_p = np.sqrt(mass * self.kT) for row, rng in enumerate(self._rngs): p = sigma_p * rng.standard_normal((na, 3)) p -= mass * (p.sum(axis=0) / mass.sum()) # no center-of-mass drift p_host[row] = p self.x = xp.asarray(x_host) self.p = xp.asarray(p_host) self.F = xp.zeros((n, na, 3), dtype=xp.float64) self.mass = xp.asarray(mass) self.qeff = None if qeff is None else xp.asarray(qeff) self.potential = xp.zeros(n, dtype=xp.float64) self._terms = xp.zeros((n, self.n_terms), dtype=xp.float64) self.zero_field = xp.zeros((n, 3), dtype=xp.float64) self._amplitude = xp.zeros((n, 3), dtype=xp.float64) # dmu/dt self._dipole_half = xp.zeros((n, 3), dtype=xp.float64) # mu half a step later self._dipole_force = xp.zeros((n, 3), dtype=xp.float64) # mu at the force time self._energy = xp.zeros(n, dtype=xp.float64) # Columns used to store calculated properties. self._property_columns = {name: column for column, name in enumerate(self.compute_names)} self._property_values = xp.empty((n, len(self.compute_names)), dtype=xp.float64) # Columns selected for output, in the requested order. self._record_columns = tuple(self._property_columns[name] for name in self.record_names) # Columns of the existing force-field energy terms. self._term_columns = {name: column for column, name in enumerate(self.ff.reported_term_names)} self._gpu_property_momenta = None if self._on_gpu: from numba import cuda from numba.cuda.random import init_xoroshiro128p_states, xoroshiro128p_dtype if any( name in self._property_columns for name in ( "kinetic_trans_au", "kinetic_rot_au", "kinetic_vib_au", *_ROTATION_COMPONENT_NAMES, ) ) or self._write_trajectory_velocities or self._write_angular_velocity_body: self._gpu_property_momenta = xp.empty_like(self.p) self.kernels = build_integrator_kernels() self.mass_flat = xp.asarray(mass.ravel()) # the kernels index by atom self.qeff_flat = xp.asarray(qeff.ravel()) # Langevin noise on the device: one block of thread streams per system, # seeded from seed + molecule_id so the block is a property of the # molecule, not of its row in this batch tpb = THREADS_PER_BLOCK self.rng_states = cuda.device_array(n * tpb, dtype=xoroshiro128p_dtype) for row, mid in enumerate(self.molecule_ids): init_xoroshiro128p_states( self.rng_states[row * tpb : (row + 1) * tpb], seed=np.uint64(self.seed + mid), ) restarting = self.restart and self.checkpoint if restarting and restart_state is not None: self.load_state_dict(restart_state) # forces at the starting geometry (a pure function of it, so this reproduces # a checkpointed force array bit for bit) if self._on_gpu: self.force_kernels.forces_gpu( self.x, self.F, self.potential, self.zero_field, self._terms ) else: self._forces_on_cpu(self.zero_field) if self.pre_nvt and not restarting: coupling_dt = self.dt try: if self.pre_nvt_timestep_fs is not None: self.dt = self.pre_nvt_timestep_fs * FS_TO_AU self.equilibrate(self.pre_nvt_duration_ps, self.pre_nvt_friction_fs) finally: self.dt = coupling_dt self.t = 0.0 # reset the clock so production dynamics start fresh # Baseline subtracted from the reported dipoles, as the LAMMPS fix's # reset_dipole does. It is captured here, after any equilibration or # restart, and is what keeps the permanent dipole of the one shared # starting geometry from adding coherently over a whole batch. if self.mu_initial is None: if self.reset_dipole: self.mu_initial = self._dipoles(self.x) else: self.mu_initial = xp.zeros((n, 3), dtype=xp.float64) output = dict( record_every_steps=self.record_every_steps, record_max_steps=self.record_max_steps, append=bool(restarting), ) if self.property_filename is not None: self._recorder = PropertyRecorder( output_filename(self.property_filename, self.molecule_ids[0]), self.record_names, self.molecule_ids, self.dt, **output, ) print( f"[{self._label}] Recording {self.record_names} to " f"{self._recorder.path}" ) if self.traj_filename is not None: self._trajectory = XYZTrajectoryWriter( output_filename(self.traj_filename, self.molecule_ids[0]), self.symbols, self.molecule_ids, self.dt, traj_content=self.traj_content, **output, ) print(f"[{self._label}] Writing the trajectory to {self._trajectory.path}")
def _should_record_properties(self, step_index): """Check whether this step needs a property record.""" recorder = self._recorder return ( recorder is not None and step_index % self.record_every_steps == 0 and ( recorder.record_max_steps is None or recorder.n_records < recorder.record_max_steps ) ) def _should_record_trajectories(self, step_index): """Check whether this step needs a trajectory record.""" trajectory = self._trajectory return ( trajectory is not None and step_index % self.record_every_steps == 0 and ( trajectory.record_max_steps is None or trajectory.n_records < trajectory.record_max_steps ) ) def _complete_property_values(self): """Fill existing energy results and derived properties.""" values = self._property_values columns = self._property_columns for name in self.compute_names: column = columns[name] if name in ( "kinetic_au", "kinetic_trans_au", "kinetic_rot_au", "kinetic_vib_au", *_ROTATION_COMPONENT_NAMES, ): # These columns are filled during integration. continue elif name == "potential_au": values[:, column] = self.potential elif name == "energy_au": values[:, column] = self._energy elif name in self._term_columns: values[:, column] = self._terms[:, self._term_columns[name]] elif name == "temperature_K": values[:, column] = ( 2.0 * values[:, columns["kinetic_au"]] / (3.0 * self.n_atoms) / K_TO_AU ) elif name == "energy_vib_au": values[:, column] = ( values[:, columns["kinetic_vib_au"]] + values[:, columns["stretch_au"]] + values[:, columns["bend_au"]] ) def _gather_property_values(self): """Select output columns and return a NumPy array.""" return to_host(self._property_values[:, list(self._record_columns)]) # ----------------------- one OBABO step under E-field --------------------------- def _dipoles(self, x): """ Return every system's dipole moment for the given positions. Parameters ---------- x : numpy.ndarray or cupy.ndarray of float, shape (num, na, 3) Atomic positions in atomic units (Bohr). Returns ------- numpy.ndarray or cupy.ndarray of float, shape (num, 3) With compiled kernels the dipole is the effective-charge sum ``sum_i q_eff_i x_i``; the NumPy reference path asks the force field. """ if self.qeff is not None: return self.xp.sum(self.qeff * x, axis=1) return np.stack([self.ff.dipole(x[d]) for d in range(self.num)]) def _forces_on_cpu(self, efield): """ Fill ``self.F`` and ``self.potential``, one system at a time. Parameters ---------- efield : numpy.ndarray of float, shape (num, 3) Effective electric field vector of every system in a.u. """ for d in range(self.num): if self.force_kernels is not None: self.potential[d] = self.force_kernels.forces_cpu( self.x[d], self.F[d], np.ascontiguousarray(efield[d], dtype=float), self._terms[d], ) else: # the force field's NumPy reference implementation forces, potential = self.ff.compute( self.x[d], efield[d], self._terms[d] ) self.F[d] = forces self.potential[d] = potential def _step_on_cpu(self, efield, c1h, noise, sample_properties=False, sample_trajectory=False): """ Advance every system by one OBABO step vectorized over the batch. Parameters ---------- efield : numpy.ndarray of float, shape (num, 3) Effective electric field vector of every system in a.u. c1h : float Langevin O half-step scaling; ``1.0`` disables the thermostat. noise : numpy.ndarray of float, shape (na, 1) Momentum noise amplitude of the Langevin half-step per atom. sample_properties : bool, default: False Fill selected kinetic-property columns before the final O half-step. sample_trajectory : bool, default: False Prepare the selected trajectory arrays before the final O half-step. Returns ------- trajectory_velocities : numpy.ndarray or None Pre-O atomic velocities, shape ``(num, n_atoms, 3)``; ``None`` when atomic velocities are not selected for this step. angular_velocity_body : numpy.ndarray or None Pre-O molecular trajectory data, shape ``(num, n_molecules, 6)``: three body-frame angular velocities followed by their three principal moments of inertia. ``None`` when angular output is not selected. """ dt, mass = self.dt, self.mass if c1h < 1.0: # O self._langevin_half_kick_on_cpu(c1h, noise) self.p += 0.5 * dt * self.F # B self.x += dt * (self.p / mass) # A self._forces_on_cpu(efield) # force at the E-field time self.p += 0.5 * dt * self.F # B # the two dipole snapshots and the energy the EM solver needs p_half = self.p + 0.5 * dt * self.F v_half = p_half / mass x_half = self.x + 0.5 * dt * v_half if self.qeff is not None: self._amplitude[:] = np.sum(self.qeff * v_half, axis=1) self._dipole_half[:] = np.sum(self.qeff * x_half, axis=1) self._dipole_force[:] = np.sum(self.qeff * self.x, axis=1) else: # no effective charges: ask the force field system by system for d in range(self.num): self._amplitude[d] = self.ff.dipole_velocity(v_half[d]) self._dipole_half[d] = self.ff.dipole(x_half[d]) self._dipole_force[d] = self.ff.dipole(self.x[d]) kinetic = 0.5 * np.sum(self.p**2 / mass, axis=(1, 2)) self._energy[:] = kinetic + self.potential trajectory_velocities = None angular_velocity_body = None if sample_properties: if "kinetic_au" in self._property_columns: self._property_values[:, self._property_columns["kinetic_au"]] = kinetic if sample_properties or (sample_trajectory and self._write_angular_velocity_body): angular_velocity_body = self._compute_molecular_kinetic( self.p, sample_trajectory=sample_trajectory, ) if sample_trajectory and self._write_trajectory_velocities: trajectory_velocities = self.p / mass if c1h < 1.0: # O self._langevin_half_kick_on_cpu(c1h, noise) return trajectory_velocities, angular_velocity_body def _langevin_half_kick_on_cpu(self, c1h, noise): """ Apply one Ornstein-Uhlenbeck half-step to the momenta of every system. Each system draws from its own generator in a fixed order, so a batch member and a single system with the same molecule ID stay identical. Parameters ---------- c1h : float Langevin O half-step scaling. noise : numpy.ndarray of float, shape (na, 1) Momentum noise amplitude of the Langevin half-step, per atom. """ shape = (self.n_atoms, 3) for d, rng in enumerate(self._rngs): self.p[d] = c1h * self.p[d] + noise * rng.standard_normal(shape) def _step_on_gpu(self, efield, c1h, noise, sample_properties=False, sample_trajectory=False): """ Advance every system by one OBABO step with four kernel launches. Parameters ---------- efield : cupy.ndarray of float, shape (num, 3) Effective electric field vector of every system in a.u., on the device. c1h : float Langevin O half-step scaling; ``1.0`` disables the thermostat. noise : numpy.ndarray of float, shape (na, 1) Momentum noise amplitude of the Langevin half-step per atom. sample_properties : bool, default: False Fill selected property columns using the state before the final Langevin O half-step. sample_trajectory : bool, default: False Prepare selected trajectory arrays from the pre-O momentum copy. Returns ------- trajectory_velocities : cupy.ndarray or None Pre-O atomic velocities, shape ``(num, n_atoms, 3)``; ``None`` when atomic velocities are not selected for this step. angular_velocity_body : cupy.ndarray or None Pre-O molecular trajectory data, shape ``(num, n_molecules, 6)``: three body-frame angular velocities followed by their three principal moments of inertia. ``None`` when angular output is not selected. """ noise_dev = self.xp.asarray(noise.ravel()) thermostat = c1h < 1.0 kinetic_column = (self._property_columns.get("kinetic_au", -1) if sample_properties else -1) sample_molecular = ((sample_properties or sample_trajectory) and self._gpu_property_momenta is not None) property_momenta = (self._gpu_property_momenta if sample_molecular else self.p) self.kernels["pre"][self.num, THREADS_PER_BLOCK]( self.x, self.p, self.F, self.mass_flat, noise_dev, self.dt, c1h, self.rng_states, thermostat, ) self.force_kernels.forces_gpu( self.x, self.F, self.potential, efield, self._terms ) self.kernels["post"][self.num, THREADS_PER_BLOCK]( self.x, self.p, self.F, self.mass_flat, noise_dev, self.qeff_flat, self.dt, c1h, self.rng_states, thermostat, self.potential, self._amplitude, self._dipole_half, self._dipole_force, self._energy, kinetic_column, self._property_values, sample_molecular, property_momenta, ) trajectory_velocities = None angular_velocity_body = None if sample_properties or sample_trajectory: from numba import cuda cuda.synchronize() if sample_properties or (sample_trajectory and self._write_angular_velocity_body): angular_velocity_body = self._compute_molecular_kinetic( property_momenta, sample_trajectory=sample_trajectory, ) if sample_trajectory and self._write_trajectory_velocities: trajectory_velocities = property_momenta / self.mass return trajectory_velocities, angular_velocity_body def _compute_molecular_kinetic(self, momenta, sample_trajectory=False): """Fill kinetic properties and optionally return angular velocities with inertia. Parameters ---------- momenta : numpy.ndarray or cupy.ndarray Atomic momenta before the final Langevin O half-step, with shape ``(num, n_atoms, 3)``. This array is only read. sample_trajectory : bool, default: False Whether this step needs a trajectory frame. Angular velocities and principal moments are returned only when angular output is also selected by ``traj_content``. Returns ------- numpy.ndarray or cupy.ndarray or None Molecular trajectory data, shape ``(num, n_molecules, 6)``: the first three columns are body-frame angular velocities in inverse atomic time, and the last three are principal moments of inertia in electron-mass times Bohr-squared units. Both follow instantaneous principal axes ordered by decreasing moment of inertia. Inactive axes have zero angular velocity; the moments retain their original eigenvalues. The basis is not made continuous between frames. Returns ``None`` when angular output is not selected for this step. """ xp = self.xp columns = self._property_columns values = self._property_values need_trans = "kinetic_trans_au" in columns need_rot_components = any(name in columns for name in _ROTATION_COMPONENT_NAMES) need_rot = ( "kinetic_rot_au" in columns or need_rot_components or (sample_trajectory and self._write_angular_velocity_body) ) need_vib = "kinetic_vib_au" in columns if not (need_trans or need_rot or need_vib): return atoms_per_molecule = self.n_atoms // self.n_molecules shape = (self.num, self.n_molecules, atoms_per_molecule, 3) momentum = momenta.reshape(shape) mass = self.mass.reshape(self.n_molecules, atoms_per_molecule) total_mass = mass.sum(axis=1) # Molecular center-of-mass velocity. velocity_com = (momentum.sum(axis=2) / total_mass[None, :, None]) if need_trans: energy_molecule = (0.5 * total_mass[None, :] * xp.sum(velocity_com**2, axis=-1)) values[:, columns["kinetic_trans_au"]] = energy_molecule.sum(axis=1) if not (need_rot or need_vib): return position = self.x.reshape(shape) # Reconstruct molecules without changing the simulation positions. if self.ff.box is not None: box = xp.asarray(self.ff.box).reshape(1, 1, 1, 3) anchor = position[:, :, :1, :] displacement = position - anchor position = anchor + (displacement - box * xp.rint(displacement / box)) mass_weights = mass[None, :, :, None] position_com = xp.sum(position * mass_weights, axis=2) / total_mass[None, :, None] relative_position = position - position_com[:, :, None, :] relative_velocity = momentum / mass_weights - velocity_com[:, :, None, :] x = relative_position[..., 0] y = relative_position[..., 1] z = relative_position[..., 2] weights = mass[None, :, :] inertia = xp.empty((self.num, self.n_molecules, 3, 3), dtype=xp.float64) inertia[..., 0, 0] = xp.sum(weights * (y*y + z*z), axis=-1) inertia[..., 1, 1] = xp.sum(weights * (x*x + z*z), axis=-1) inertia[..., 2, 2] = xp.sum(weights * (x*x + y*y), axis=-1) inertia[..., 0, 1] = inertia[..., 1, 0] = -xp.sum(weights * x * y, axis=-1) inertia[..., 0, 2] = inertia[..., 2, 0] = -xp.sum(weights * x * z, axis=-1) inertia[..., 1, 2] = inertia[..., 2, 1] = -xp.sum(weights * y * z, axis=-1) angular_momentum = xp.sum(xp.cross(relative_position, mass_weights * relative_velocity), axis=2) # Principal axes ordered by decreasing moment of inertia. principal_moments, principal_axes = xp.linalg.eigh(inertia) principal_moments = principal_moments[..., ::-1] principal_axes = principal_axes[..., :, ::-1] # Use the same relative cutoff as the previous pseudoinverse. valid = principal_moments > 1e-10 * xp.maximum(principal_moments[..., :1], 0.0) safe_moments = xp.where(valid, principal_moments, 1.0) # Angular momentum and angular velocity in the principal-axis frame. angular_momentum_body = (xp.swapaxes(principal_axes, -1, -2) @ angular_momentum[..., None])[..., 0] angular_velocity_body = xp.where(valid, angular_momentum_body / safe_moments, 0.0) # Transform back for the existing vibrational-velocity calculation. angular_velocity = (principal_axes @ angular_velocity_body[..., None])[..., 0] if need_rot_components: component_energy = 0.5 * angular_momentum_body * angular_velocity_body for axis, name in enumerate(_ROTATION_COMPONENT_NAMES): if name in columns: values[:, columns[name]] = component_energy[..., axis].sum(axis=1) if "kinetic_rot_au" in columns: energy_molecule = 0.5 * xp.sum(angular_velocity * angular_momentum, axis=-1) values[:, columns["kinetic_rot_au"]] = energy_molecule.sum(axis=1) if need_vib: rotational_velocity = xp.cross(angular_velocity[:, :, None, :], relative_position) vibrational_velocity = relative_velocity - rotational_velocity energy_molecule = 0.5 * xp.sum(weights * xp.sum(vibrational_velocity**2, axis=-1), axis=-1) values[:, columns["kinetic_vib_au"]] = energy_molecule.sum(axis=1) if sample_trajectory and self._write_angular_velocity_body: # Pack only the trajectory output; energy calculations above use 3-component omega. return xp.concatenate((angular_velocity_body, principal_moments), axis=-1)
[docs] def step(self, efield_au): """ Advance every system by one OBABO velocity-Verlet step under the field. Parameters ---------- efield_au : numpy.ndarray of float, shape (num, 3) Contiguous host array of effective electric field vectors in a.u. Returns ------- MDStepResult Columnar amplitude (``dmu/dt``), half-step dipole, force-time dipole, and energy for every system. Raises ------ RuntimeError If called before :meth:`initialize`. ValueError If ``efield_au`` does not have shape ``(num, 3)``. """ if self.x is None: raise RuntimeError(f"{self._label}.step() called before initialize().") field = np.ascontiguousarray(efield_au, dtype=np.float64) if field.shape != (self.num, 3): raise ValueError( f"efield_au must have shape ({self.num}, 3); got {tuple(field.shape)}." ) next_step = self._step_index + 1 sample_properties = self._should_record_properties(next_step) sample_trajectory = self._should_record_trajectories(next_step) field = self.xp.asarray(field) step_method = self._step_on_gpu if self._on_gpu else self._step_on_cpu trajectory_velocities, angular_velocity_body = step_method( field, self.c1h, self.noise, sample_properties=sample_properties, sample_trajectory=sample_trajectory, ) self._dipole_half -= self.mu_initial # report relative to time zero self._dipole_force -= self.mu_initial self.t += self.dt self._step_index = next_step # Selected properties, shared by CPU and GPU. if sample_properties: self._complete_property_values() values = self._gather_property_values() self._recorder.record( self._step_index, self.t, values, ) # Independent trajectory output from the pre-O state. if sample_trajectory: positions = None velocities = None angular_velocity_atoms = None if self.traj_content in ("positions", "all"): positions = to_host(self.x) if self.traj_content in ("velocities", "all"): velocities = to_host(trajectory_velocities) if angular_velocity_body is not None: # Repeat each molecule's [omega_1, omega_2, omega_3, I_1, I_2, I_3]. atoms_per_molecule = self.n_atoms // self.n_molecules angular_velocity_atoms = np.repeat( to_host(angular_velocity_body), atoms_per_molecule, axis=1, ) self._trajectory.write( self._step_index, self.t, positions_bohr=positions, velocities_au=velocities, angular_velocity_body_au=angular_velocity_atoms, ) return MDStepResult( amplitude_au=to_host(self._amplitude), dipole_half_au=to_host(self._dipole_half), dipole_force_au=to_host(self._dipole_force), energy_au=to_host(self._energy), )
[docs] def equilibrate(self, duration_ps, friction_fs, temperature_K=None): """ Run a field-free Langevin trajectory to thermalize every system. Each system carries its own random stream and remains uncorrelated with other systems. Nothing is recorded and the dipole baseline is untouched. Parameters ---------- duration_ps : float Equilibration length in picoseconds. friction_fs : float Langevin relaxation time in femtoseconds. temperature_K : float, optional Bath temperature; the engine's own ``temperature_K`` by default. Returns ------- int Number of MD steps taken. """ kT = self.kT if temperature_K is None else K_TO_AU * float(temperature_K) gamma = 1.0 / (float(friction_fs) * FS_TO_AU) c1h = float(np.exp(-0.5 * gamma * self.dt)) noise = np.sqrt(self._mass_host * kT * (1.0 - c1h**2)) n_steps = int(round(float(duration_ps) * 1000.0 * FS_TO_AU / self.dt)) for _ in range(n_steps): if self._on_gpu: self._step_on_gpu(self.zero_field, c1h, noise) else: self._step_on_cpu(self.zero_field, c1h, noise) self.t += self.dt return n_steps
[docs] def set_thermostat(self, thermostat, temperature_K=None, friction_fs=None): """ Switch the production ensemble after :meth:`initialize`. Parameters ---------- thermostat : {'nve', 'nvt'} The ensemble subsequent :meth:`step` calls integrate. temperature_K : float, optional New target temperature in Kelvin; unchanged by default. friction_fs : float, optional New Langevin relaxation time in femtoseconds; unchanged by default. """ thermostat = str(thermostat).lower() if thermostat not in ("nve", "nvt"): raise ValueError("thermostat must be 'nve' or 'nvt'.") if self.dt <= 0.0: raise RuntimeError("set_thermostat() requires initialize() first.") self.thermostat = thermostat if temperature_K is not None: self.temperature_K = float(temperature_K) self.kT = K_TO_AU * self.temperature_K if friction_fs is not None: self.friction_fs = float(friction_fs) if self.thermostat == "nvt": gamma = 1.0 / (self.friction_fs * FS_TO_AU) self.c1h = float(np.exp(-0.5 * gamma * self.dt)) else: self.c1h = 1.0 self.noise = np.sqrt(self._mass_host * self.kT * (1.0 - self.c1h**2))
# --------------------- snapshot / checkpoint state ------------------------------
[docs] def snapshot(self): """ Return a deep-copied snapshot of the propagating state. Returns ------- dict The clock, positions, momenta, forces, and random-generator states. """ snap = { "time": self.t, "x": self.x.copy(), "p": self.p.copy(), "F": self.F.copy(), "rng": [rng.bit_generator.state for rng in self._rngs], } if self._on_gpu: # the device streams draw the GPU Langevin noise snap["rng_states"] = self.rng_states.copy_to_host() return snap
[docs] def restore(self, snapshot): """ Restore the propagating state from a snapshot. Parameters ---------- snapshot : dict A snapshot produced by :meth:`snapshot`. """ self.t = snapshot["time"] self.x[:] = snapshot["x"] self.p[:] = snapshot["p"] self.F[:] = snapshot["F"] for rng, state in zip(self._rngs, snapshot["rng"]): rng.bit_generator.state = state if self._on_gpu and "rng_states" in snapshot: from numba import cuda self.rng_states = cuda.to_device(snapshot["rng_states"])
[docs] def state_dict(self): """ Return the checkpointable state as host arrays. Returns ------- dict ``time`` (float), ``x``/``p``/``F`` of shape ``(num, na, 3)``, ``mu_initial`` of shape ``(num, 3)`` and the ``molecule_ids``. """ return { "time": self.t, "x": to_host(self.x), "p": to_host(self.p), "F": to_host(self.F), "mu_initial": to_host(self.mu_initial), "molecule_ids": np.asarray(self.molecule_ids), }
[docs] def load_state_dict(self, state): """ Restore a checkpointed state produced by :meth:`state_dict`. Parameters ---------- state : dict ``time``, ``x``, ``p``, ``F`` and optionally ``mu_initial`` (an old checkpoint without it keeps ``mu_initial`` unset, so the baseline is recaptured from the restored geometry). Raises ------ ValueError If the state holds a differently shaped batch. """ if self.x is None: raise RuntimeError("load_state_dict() requires initialize() first.") x = np.asarray(state["x"]) if x.shape != (self.num, self.n_atoms, 3): raise ValueError( f"Checkpoint holds {x.shape} state, expected " f"{(self.num, self.n_atoms, 3)}." ) self.t = float(state["time"]) self.x[:] = self.xp.asarray(x) self.p[:] = self.xp.asarray(state["p"]) self.F[:] = self.xp.asarray(state["F"]) if "mu_initial" in state: # keep reporting against the original baseline if self.mu_initial is None: self.mu_initial = self.xp.asarray(state["mu_initial"]) else: self.mu_initial[:] = self.xp.asarray(state["mu_initial"])
# ----------------------- internal helper / teardown -----------------------------
[docs] def close_outputs(self): """Close the output files if any are being written.""" for name in ("_recorder", "_trajectory"): writer = getattr(self, name) if writer is not None: writer.close() setattr(self, name, None)
[docs] def close(self): """ Close the output files and drop the batch state (device buffers included). """ self.close_outputs() self.x = self.p = self.F = None self._terms = None self._property_values = None self._gpu_property_momenta = None self._amplitude = self._dipole_half = self._dipole_force = self._energy = None self.mu_initial = None self.potential = None self.force_kernels = None